TP-100-VGA

10.1" 16:10 WXGA P-Cap Multi-Touch Teach Pendant, VGA Input
  • Main Feature
  • Modern, ergonomic, user-friendly and operated comfortably
  • Multi channels deadman switch and E-Stop button
  • Full IP65 protectione
  • 10.1" WXGA 1280 x 800 500 nits LED panel
  • 10 points projected capacitive touch with Full IP65 protection
  • Two external USB 2.0 for data backup
  • An emergency-stop button is available as further safety element
  • Anti-vibration/shock IEC/EN 61131-2 compliance
  • EMC (IEC/EN 61000-6-2/4, IEC/EN 61131-2) compliance
  • System frame ground protection (GPE) design
Add to Inquiry
Datasheet(PDF)
Panel 10.1”, 16:10, WXGA, 1280 x 800 Luminance: 500 cd/m² Contrast ratio: 800:1 LCD color: 16.7M Viewing angle: 85 (U), 85 (D), 85 (L), 85 (R) Backlight: LED
Touch Touch: 10 points P-Cap Touch light transmission: 87% Touch interface: USB Anti-scratch surface: 7H hardness
Safety Elements Emergency stop button (2 NC channels, B10d=130,000)
- Contact function: latching
- Reset: by rotating
3-position Deadman switch (3 channels 2 NO &1 NC, B10d=100,000)
Operating Elements 2-position key switch (2 channels)
System TP-100-VGA: VGA input USB2.0 upstream
Interface Data back-up: 2 x USB 2.0 Controle connector: HDB-44 female
- Removable HDB-44 control cable (optional)

- Including power, E-stop buttons, deadman switch, key switch, USB 2.0 and VGA signals
Ratings Power supply voltage: 24 Vdc (19.2 to 28.8 Vdc) Current consumption:
- TP-100-VGA 0.625A at 24Vdc (max.)
Mechanical Dimension: 297.3 x 257.2 x57.2 mm (78.5mm including E-stop button) Weight (without external control cable):
- TP100-VGA 1.5Kg
Front bezel: aluminum magnesium alloy; color: Pantone 8424C Back cover: ABS+PC; color: Pantone 432C IP protection class: Full IP65
Environment Operatng temperature: 0°C to 50°C Storage temperature: -20°C to 75°C Operating humidity: 5%~90% relative humidity, non-condensing Vibration resistance/shock-proof/free-fall according to EN 61131-2
Certifications CE (Emission EN61000-6-4; Immunity EN61000-6-2 for installation in industrial environments) FCC Class A
Add to Inquiry